264 research outputs found

    Highly efficient coupling between a monolithically integrated photonic crystal cavity and a bus waveguide

    Get PDF
    We experimentally demonstrate a new optical filter design comprising of a photonic crystal cavity and a low index bus waveguide which are monolithically integrated on a silicon-on-insulator (SOI) platform. We have fabricated oxide clad PhC cavities with a silicon nitride waveguide positioned directly above, such that there is an overlap between the evanescent tails of the two modes. We have realised an extinction ratio of 7.5dB for cavities with total Q of 50,000.Postprin

    Performance limitations of resonant refractive index sensors with low-cost components

    Get PDF
    Resonant biosensors are attractive for diagnostics because they can detect clinically relevant biomarkers with high sensitivity and in a label-free fashion. Most of the current solutions determine their detection limits in a highly stabilised laboratory environment, which does, however, not apply to real point-of-care applications. Here, we consider the more realistic scenario of low-cost components and an unstabilised environment and consider the related design implications. We find that sensors with lower quality-factor resonances are more fault tolerant, that a filtered LED lightsource is advantageous compared to a diode laser, and that a CMOS camera is preferable to a CCD camera for detection. We exemplify these findings with a guided mode resonance sensor and experimentally determine a limit of detection of 5.8 ± 1.7×10−5 refractive index units (RIU), which is backed up by a model identifying the various noise sources. Our findings will inform the design of high performance, low cost biosensors capable of operating in a real-world environment

    Dielectric metasurface for high-precision detection of large unilamellar vesicles.

    Get PDF
    Extracellular vesicles (EVs) are very promising biomarkers for the diagnosis of various diseases, including cardiovascular, infectious and neurodegenerative disorders. Of particular relevance is their importance in cancer liquid biopsy, where they play a key role in the early detection and monitoring of the tumour. A number of technologies have recently been developed to improve the performance of current EV detection methods, but a technique that can provide high resolution, high accuracy and a multiplexing capability for the detection of several biomarkers in parallel remains a challenge in this field. Here, we demonstrate the detection of large unilamellar vesicles, which are excellent models of EVs, down to a concentration <103 EV ml−1 (<10 pM) using a dielectric resonant metasurface. This result represents an improvement in performance and functionality compared to competing plasmonic and electrochemical modalities and is due to the strong resonance amplitude and high Q-factor of our metasurface. We also verify the selectivity of the approach by detecting vesicles that have been surface-functionalised with a CD9 protein. The ease of integration of our method into a point-of-care instrument offers a path towards personalised cancer medicine

    Slow-light and evanescent modes at interfaces in photonic crystal waveguides: optimal extraction from experimental near-field measurements

    Get PDF
    We develop a systematic approach for simultaneous extraction of the dispersion relations and profiles of multiple modes in periodic waveguides though a special global optimization procedure applied to near-field electric field measurements in the waveguide plane. We apply this method to perform in-depth analysis of experimental data on wave propagation close to an interface between waveguide sections with different dispersion characteristics, and we successfully identify several modes contributing to the experimentally measured fields. We find clear evidence that when the group velocity is reduced across the interface, evanescent modes that facilitate the excitation of propagating slow-light waves appear, confirming previous theoretical predictions. (C) 2011 Optical Society of AmericaPublisher PDFPeer reviewe

    Synthesis and biochemical evaluation of cephalosporin analogues equipped with chemical tethers

    Get PDF
    Molecular probes typically require structural modifications to allow for the immobilisation or bioconjugation with a desired substrate but the effects of these changes are often not evaluated. Here, we set out to determine the effects of attaching functional handles to a first-generation cephalosporin. A series of cephalexin derivatives was prepared, equipped with chemical tethers suitable for the site-selective conjugation of antibiotics to functionalised surfaces. The tethers were positioned remotely from the β-lactam ring to ensure minimal effect to the antibiotic's pharmacophore. Herein, the activity of the modified antibiotics was evaluated for binding to the therapeutic target, the penicillin binding proteins, and shown to maintain binding interactions. In addition, the deactivation of the modified drugs by four β-lactamases (TEM-1, CTX-M-15, AmpC, NDM-1) was investigated and the effect of the tethers on the catalytic efficiencies determined. CTX-M-15 was found to favour hydrolysis of the parent antibiotic without a tether, whereas AmpC and NDM-1 were found to favour the modified analogues. Furthermore, the antimicrobial activity of the derivatives was evaluated to investigate the effect of the structural modifications on the antimicrobial activity of the parent drug, cephalexin

    Ultra-high Q/V hybrid cavity for strong light-matter interaction

    Get PDF
    The ability to confine light at the nanoscale continues to excite the research community, with the ratio between quality factor Q and volume V, i.e., the Q/V ratio, being the key figure of merit. In order to achieve strong light-matter interaction, however, it is important to confine a lot of energy in the resonant cavity mode. Here, we demonstrate a novel cavity design that combines a photonic crystal nanobeam cavity with a plasmonic bowtie antenna. The nanobeam cavity is optimised for a good match with the antenna and provides a Q of 1700 and a transmission of 90%. Combined with the bowtie, the hybrid photonic-plasmonic cavity achieves a Q of 800 and a transmission of 20%, both of which remarkable achievements for a hybrid cavity. The ultra-high Q/V of the hybrid cavity is of order of 106 (λ/n)−3, which is comparable to the state-of-the-art of photonic resonant cavities. Based on the high Q/V and the high transmission, we demonstrate the strong efficiency of the hybrid cavity as a nanotweezer for optical trapping. We show that a stable trapping condition can be achieved for a single 200 nm Au bead for a duration of several minutes (ttrap > 5 min) and with very low optical power (Pin = 190 μW)

    Chirped guided-mode resonance biosensor

    Get PDF
    Advanced biomedical diagnostic technologies fulfill an important role in improving health and well-being in society. A large number of excellent technologies have already been introduced and have given rise to the "lab-on-a-chip" paradigm. Most of these technologies, however, require additional instrumentation for interfacing and readout, so they are often confined to the laboratory and are not suitable for use in the field or in wider clinical practice. Other technologies require a light coupling element, such as a grating coupler or a fiber coupler, which complicates packaging. Here, we introduce a novel biosensor based on a chirped guided-mode resonant grating. The chirped grating combines the sensing function with the readout function by translating spectral information into spatial information that is easily read out with a simple CMOS camera. We demonstrate a refractive index sensitivity of 137 nm/RIU and an extrapolated limit of detection of 267 pM for the specific binding of an immunoglobulin G antibody. The chirped guided-mode resonance approach introduces a new degree of freedom for sensing biomedical information that combines high sensitivity with autonomous operation. We estimate that the cost of components is U.S. $10 or less when mass manufactured, so the technology has the potential to truly transform point-of-care applications

    Chirped guided-mode resonance biosensor

    Get PDF
    Advanced biomedical diagnostic technologies fulfill an important role in improving health and well-being in society. A large number of excellent technologies have already been introduced and have given rise to the "lab-on-a-chip" paradigm. Most of these technologies, however, require additional instrumentation for interfacing and readout, so they are often confined to the laboratory and are not suitable for use in the field or in wider clinical practice. Other technologies require a light coupling element, such as a grating coupler or a fiber coupler, which complicates packaging. Here, we introduce a novel biosensor based on a chirped guided-mode resonant grating. The chirped grating combines the sensing function with the readout function by translating spectral information into spatial information that is easily read out with a simple CMOS camera. We demonstrate a refractive index sensitivity of 137 nm/RIU and an extrapolated limit of detection of 267 pM for the specific binding of an immunoglobulin G antibody. The chirped guided-mode resonance approach introduces a new degree of freedom for sensing biomedical information that combines high sensitivity with autonomous operation. We estimate that the cost of components is U.S. $10 or less when mass manufactured, so the technology has the potential to truly transform point-of-care applications
    corecore